Boiler room with one exchanger
Our company also manufactures boilers from 150 – 1000 litres. Each boiler can be manufactured with or without resistance. All boilers rooms are vertical with a leatherette casing or even with a steel casing, if installed outdoors.
| Exchanger S1 input/output | 1″ |
| Maximum proposed collector surface of solar collectors | 2,7 m2 |
| Exchanger surface | 0,75 m2 |
| Exchanger power | 13,8 kw |
| ΔT water use: 15° / 60° C) | 900 l/h |
| Electrical resistance power | 4 Kw |
| Cold water inlet | 1″ |
| Hot water outlet | 1″ |
| Recirculation | 1″ |
| Weight | 61 kg |
| Height | 1260 mm |
| Diameter | 530 mm |
| Insulation thickness | 55 mm |
| Exchanger S1 input/output | 1″ |
| Maximum proposed collector surface of solar collectors | 4 m2 |
| Exchanger surface | 0,90 m2 |
| Exchanger power | 15 kw |
| ΔT water use: 15° / 60° C) | 900 l/h |
| Electrical resistance power | 4 Kw |
| Cold water inlet | 1″ |
| Hot water outlet | 1″ |
| Recirculation | 1″ |
| Weight | 85 kg |
| Height | 1260mm |
| Diameter | 580 mm |
| Insulation thickness | 55 mm |
| Exchanger S1 input/output | 1″ |
| Maximum proposed collector surface of solar collectors | 6 m2 |
| Exchanger surface | 1,6 m2 |
| Exchanger power | 23,5 kw |
| ΔT water use: 15° / 60° C) | 900 l/h |
| Electrical resistance power | 4 Kw |
| Cold water inlet | 1″ |
| Hot water outlet | 1″ |
| Recirculation | 1″ |
| Weight | 110 kg |
| Height | 1770mm |
| Diameter | 580 mm |
| Insulation thickness | 55 mm |
| Exchanger S1 input/output | 1″ |
| Maximum proposed collector surface of solar collectors | 10 m2 |
| Exchanger surface | 2 m2 |
| Exchanger power | 26,5 kw |
| ΔT water use: 15° / 60° C) | 900 l/h |
| Electrical resistance power | 6 Kw |
| Cold water inlet | 1“ |
| Hot water outlet | 1“ |
| Recirculation | 1″ |
| Weight | 141 kg |
| Height | 1770mm |
| Diameter | 700 mm |
| Insulation thickness | 55 mm |
| Exchanger S1 input/output | 1″ |
| Maximum proposed collector surface of solar collectors | 16 m2 |
| Exchanger surface | 2,4 m2 |
| Exchanger power | 29,3 kw |
| ΔT water use: 15° / 60° C) | 900 l/h |
| Electrical resistance power | 6 Kw |
| Cold water inlet | 1½“ |
| Hot water outlet | 1½“ |
| Recirculation | 1″ |
| Weight | 228 kg |
| Height | 1800mm |
| Diameter | 1000mm |
| Insulation thickness | 100 mm |
| Exchanger S1 input/output | 1″ |
| Maximum proposed collector surface of solar collectors | 20 m2 |
| Exchanger surface | 3 m2 |
| Exchanger power | 38,7 kw |
| ΔT water use: 15° / 60° C) | 900 l/h |
| Electrical resistance power | 2×6 Kw |
| Cold water inlet | 1½“ |
| Hot water outlet | 1½“ |
| Recirculation | 1″ |
| Weight | 243 kg |
| Height | 2000mm |
| Diameter | 1000mm |
| Insulation thickness | 100 mm |